Regency G36D-NG NATURAL GAS, G36D-LP PROPANE Installation, Ultraglow Direct Vent System Flex

Models: G36D-NG NATURAL GAS G36D-LP PROPANE

1 40
Download 40 pages 45.99 Kb
Page 15
Image 15
Note: 1) A maximum of two 90o elbows are permitted.

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

ULTRAGLOW DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

The diagram below shows examples of horizontal termination arrangements using two 90o elbows (two 45o elbows equal one 90o elbow).

Note: 1) A maximum of two 90o elbows are permitted.

2)A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90o elbows are used.

3)Minimum distance between elbows is 2 ft. (0.6m).

4)Determine the permitted range of horizontal termination arrangements by using chart on page 14 and deducting 3 ft. (0.9m) from the maximum horizontal distance for the second 90o elbow.

If length "B" is increased, length "A" must be decreased by a corresponding amount.

All Rigid Pipe Systems 4" inner diameter

6-5/8" outer diameter

UltraGlow Flex Vent 4" inner diameter

6-7/8" inner diameter

A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.

Maintain clearances to combustibles as listed on pages 7 and 8.

Horizontal vent must be supported every 3 feet.

Firestops are required at each floor level and whenever passing through a wall.

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

15