OPERATING INSTRUCTIONS

OPERATION

NORMAL OPERATING

SOUNDS OF

GAS APPLIANCES

It is possible that you will hear some sounds from yourgasappliance.Thisisperfectlynormaldueto the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.

Burner Tray:

The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Pilot Flame:

While the pilot fl ame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox:

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

OPERATION DURING

POWER OUTAGE

In the event of a power failure, the unit will be fully functional for the fi rst 45 minutes using the backup-battery system.

If power resumes within the fi rst 45 minutes you can continue using the unit as normal.

If power is restored after 45 minutes you will need to reset the unit as follows;

a)Remove the left side exterior brick panel.

b)Hold the reset button for 3 to 5 seconds or until the LED stops blinking.

c)Press and release the ON/OFF button once on the Remote Control.

Reset Button

Located on the left hand side of the fi rebox behind the exterior brick panel.

BACKUP BATTERY

Listed below are approved battery types that can be used for replacement:

a)Powersonic 1.3AH

b)Panasonic 1.3AH

c)Henda 1.3AH

d)Magnacharge 1.3AH

CAUTION:

Risk of Energy Hazard, 12V, 1.3 Amphere-hour battery. Before replacing batteries, remove con- ductivejewelrysuchaschains,wristwatches,and rings. High energy through conductive materials could cause severe burns.

Dispose of batteries at an authorized battery disposal site. Do not dispose of batteries in a fi re. The batteries may explode.

Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.

NOTE: This must only be performed by a quali- fi ed installer.