INSTALLATION

INSTALLATION

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

 

Simpson

 

Simpson

 

Selkirk

Metal-Fab®

 

®

Direct Vent GS®

 

 

 

Direct Vent Pro

 

Discontinued

Direct-Temp™

Sure Seal

 

 

 

 

 

 

Round Support / Radiation Sheild

N/A

 

N/A

 

N/A

N/A

Flat Flashing

 

N/A

 

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

Attic Insulation Shield 12”

58DVA-IS - N/A from FPI

58DVA-IS - N/A from FPI

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Basic Horizontal Termination Kit (A)

N/A

 

N/A

 

5DT-HKA

N/A

Horizontal Termination Kit (B)

58DVA-KHA

 

N/A

 

5DT-HKB

N/A

Vertical Termination Kit

58DVA-VCH

 

1291

 

 

5DT-VKC

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Wind Vertical Cap

N/A

 

N/A

 

N/A

N/A

High Wind Horizontal Cap

DISC.

 

1285

 

 

N/A

N/A

Horizontal Square Termination Cap

N/A

 

1284

 

 

5DT-HHC

5DHT

Vertical Termination Cap

N/A

 

N/A

 

5DT-HVC

5DVT

Storm Collar

 

58DVA-SC

 

1253

 

 

5DT-SC

5DSC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustable Flashing, 0/12-6/12

58DVA-F6

 

1243

 

 

5DT-AF6

5DF

Adjustable Flashing, 6/12-12/12

58DVA-F12

 

1243S

 

5DT-AF12

5DF-12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vinyl Siding Standoff

58DVA-VSS

 

1250

 

 

5DT-VS

5DVS

Vinyl Siding Shield Plate

N/A

 

N/A

 

5DT-VSP

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Snorkel Termination 14”

58DVA-SNK14

 

1282

 

 

5DT-ST14

5DST14

Snorkel Termination 36”

N/A

 

1281

 

 

5DT-ST36

5DST36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restrictor Disk

 

58DVA-RD

 

N/A

 

N/A

N/A

Colinear Flex Liner Adapter (3” Ø)

N/A

 

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FPI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

946-604/P

Simpson Direct Vent Vent Guard (Optional)

 

946-623/P

 

AstroCap XL Horizontal Cap

 

770-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

 

946-506/P

 

Vent Guard (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

946-625

 

Vinyl Siding Standoff - AstroCap XL

 

 

 

 

 

 

 

 

 

 

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (5DDA) or 90º Starter Elbow (5D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994).

L676 & L900 Direct Vent Fireplace

IMPORTANT NOTE

A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.

The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.

Only the AstroCap XL and Snorkels are certified for horizontal terminations.

Offset Pipe Selection:

Use this table to determine offset pipe lengths.

Pipe Length

5” x 8” Venting

 

 

Run (X)

Rise (Y)

 

 

 

 

0”(0mm)

5-11/16”(144mm)

15-5/16”(389mm)

 

 

 

6”(152mm)

8-13/16”(224mm)

18-7/16”(468mm)

 

 

 

9”(229mm)

10-15/16”(278mm)

20-9/16”(522mm)

 

 

 

12”(305mm)

13”(330mm)

22-11/16”(576mm)

 

 

 

24”(610mm)

21-7/16”(697mm)

31-1/16”(789mm)

 

 

 

36”(914mm)

29-13/16”(757mm)

39-7/16”(1002mm)

 

 

 

48”(1219mm)

38-1/4”(972mm)

47-7/8”(1216mm)

 

 

 

L

Y

X

For specific instructions or details on particular venting components please visit the following websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

Metal-Fab Sure Seal: www.mtlfab.com

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fire hazard.

18

Regency® L900E Direct Vent Gas Fireplace

Page 18
Image 18
Regency L900E-NG installation manual L676 & L900 Direct Vent Fireplace