INSTALLATION

INSTALLATION

a)Interior Brick Panels

b)Log Set

c)Exterior Brick Panels

d)Remote Control - refer to "Matching Remote Handset & Control Box ID Code" section.

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label 48,000 (NG)

A)Flat on Wall

B)Flat on Wall Corner

C)Recessed into Wall/Alcove

D)Corner

Diagram 1

HEAT RELEASE KIT

The Heat Release Kit expels warm air from the

replace to the outside of the building, allowing thefireplacetobeoperatedwithlessheatentering the room. The kit may be used on either the left or right side.

See Heat Release installation manual for complete details and clearances from side only.

HEARTH

REQUIREMENTS

Btu/h, 46,500 (LP) Btu/h) after burning

appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow

the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fi replace, ensure that the clearances are met.

2)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

3)The L900E Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.

4)This appliance is Listed for bedroom installations using the standard FireWizard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The L900E Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details.

6)We recommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "ExteriorVent TerminationLocations" section.

HEATWAVE

DUCT KIT

The HeatWave Air Duct Kit increases the effectivenessofyourfireplacebydispersingwarm air from the fi replace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time.

See HeatWave installation manual for complete details and clearances from side only.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

Aminimum 33-1/8" (838mm) wide x 12" (305mm) deep x 2" (51mm) thick non-combustible hearth is required if the fi nished fl oor is not fl ush with the base of the unit. The maximum height between the fi nished fl oor and sub-fl oor is 1" (25mm).

 

-1/8"

(838mm)

 

 

12"

33

 

 

 

(305mm)

 

 

2” (51mm)

NOTE: No hearth is required when the unit is

ush with the fi nished fl oor as shown below.

The minimum floorclearance must be maintained from the top surface of the carpet, etc. to the unit base.

8

Regency® L900E Direct Vent Gas Fireplace

Page 8
Image 8
Regency L900E-NG Heat Release KIT, Hearth Requirements, Manufactured Mobile Home Additional Requirements