INSTALLATION

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Caution Requirements

The top, back and sides of the fi replace are defi ned by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction.

Clearance to Combustibles from:

Back 0" (0mm)

Side 0" (0mm)

Floor 0" (0mm)

Minimum Clearance from Top of Front Facing:

Mantel

min. 17-1/2"

(445mm)

Ceiling

49"

(1245mm) from top of front facing

Side Wall to Unit:

16"* (406mm)

Horizontal Vent Clearances to Combustibles:

Top

3"

(76mm)

Side

2"

(51mm)

Bottom

2"

(51 mm)

Vertical Vent Clearances to Combustibles:

All Sides

2"

(51mm)

Alcove Clearances:

Min. Depth

36"

(914mm)

Min. Width*

84"

(2134mm)

Min. Height

84"

(2134mm)

* Alcove side wall must have a minimum of 16" (406mm) clearance on one side.

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

INSTALLATION

Regency® L900E Direct Vent Gas Fireplace

9

Page 9
Image 9
Regency L900E-NG installation manual Clearances