Regency P33-LP4 installation manual Installation, Horizontal Venting with Three 3 90o Elbows

Models: P33-LP4

1 52
Download 52 pages 40.32 Kb
Page 21
Image 21
Horizontal Venting with Three (3) 90o Elbows

INSTALLATION

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H

V+V1

H+H1

With these

options,

 

 

 

 

 

 

 

 

maximum total

pipe

 

A)

2'

Min.

1' Max.

3'

Min.

4' Max.

 

length is 30 feet with

 

 

 

 

 

 

 

 

minimum of

12

feet

 

B)

3'

Min.

2' Max.

4'

Min.

5' Max.

 

total vertical

and

 

C)

4'

Min.

3' Max.

6'

Min.

6' Max.

maximum 9 feet total

 

horizontal.

 

 

 

D)

5'

Min.

4' Max.

8'

Min.

7' Max.

P l e a s e

n o t e

 

E)

6'

Min.

5' Max.

10'

Min.

8' Max.

minimum

1

foot

 

 

 

 

 

 

 

 

between 90o elbows

 

F)

7'

Min.

6' Max.

12'

Min.

9' Max.

 

is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V

 

H

V+V1

With these options,

 

 

 

 

 

maximum total pipe

A)

1' Min.

4'

Max.

2' Min.

length is 30 feet with

 

 

 

 

 

minimum of 6 feet total

B)

2' Min.

5'

Max.

3' Min.

vertical and maximum 8

C)

3' Min.

6'

Max.

4' Min.

feet total horizontal.

 

D)

4' Min.

7'

Max.

5' Min.

Please note minimum

 

 

 

 

 

1 foot between 90o

E)

5' Min.

8'

Max.

6' Min.

elbows is required.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H + H1

V

With these options, maximum

 

 

 

 

total pipe length is 30 feet

A)

2'

Max.

2' Min.

with minimum of 6 feet total

 

 

 

 

vertical and maximum 6 feet

B)

3'

Max.

3' Min.

total horizontal.

C)

4'

Max.

4' Min.

Please note minimum 1

D)

5'

Max.

5' Min.

foot between 90o elbows is

 

 

 

 

required.

E)

6'

Max.

6' Min.

 

For additional vertical venting with 2 x 90o elbows, refer to "Rigid Pipe Venting Arrangements" Section.

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

21

Page 21
Image 21
Regency P33-LP4 Installation, Horizontal Venting with Three 3 90o Elbows, Vertical Venting with Two 2 90o Elbows