INSTALLATION
FRAMING AND FINISHING
1)Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to
Install Side Nailing Strips, and Top Facing Supportbeforeunitisslippedintoposition. See "Unit Assembly Prior to Installation" Section
2)Frame in the enclosure for the unit with framing material.
Vertical Termination or
Vertical Rise with Horizontal
Termination
For Both Rigid & Flex
NOTE: If this is an outside corner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap. (For example
Rear Termination
For Rigid Vent
For Flex Vent
For Both Rigid & Flex
NOTE: If this isan outsidecorner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap. (For Example
3)For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.)
4)The top of the unit must not be closer than 30" (762mm) to the ceiling.
5)Combustible material may be brought up to the top and sides of the unit and be covered with ceramic tiles, bricks, rock or other suitable combustible fi nishing materials.
Note: Theunitdoesnothavetobecompletely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustiblebuildingmaterialscanbe laid directly on top of the standoffs. You must maintain clearance from the vent to combustible materials for flex or for Rigid Vent (Refer to "Clearances" Section).
| Rigid Vent |
| |
Minimum Clearances |
| ||
| Top Header |
| |
|
| 10" (254mm) |
|
1/2" |
| dia. Hole through |
|
(13mm) | wall for |
| |
Drywall |
| ||
|
|
| |
| 30” | (762mm) | |
(38mm) |
| ||
|
|
| |
4" | 3" |
| |
(102mm)(76mm) | (419mm) |
| |
Opening for gas | Minimum |
| |
connection |
|
| |
| Flex Vent |
| |
Minimum Clearances |
| ||
| Top Header |
| |
1/2" |
| 10" (254mm) |
|
| dia. Hole through | ||
(13mm) |
| ||
Drywall |
| wall for Flex |
|
| 26” | (660mm) | |
(38mm) |
| ||
|
|
| |
4" | 3" |
| |
(102mm)(76mm) | (324mm) |
| |
Opening for gas | Minimum |
| |
connection |
|
|
6)Use steel studs for framing where the
The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.
Regency® | 9 |