INSTALLATION

INSTALLATION

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location

(Refer to "Locating Your Fireplace" Section)

b)Clearances to Combustibles (Refer to "Clearances" Section)

c)Mantle Clearances

(Refer to "Combustible Mantels" Section)

d)Framing & Finishing Requirements (Refer to "Framing & Finishing" Section)

e)Venting Requirements (Refer to "Venting" Sections)

2)Assemble Top Facing Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section). NOTE: Must be done before installing unit into fi replace.

3)Install vent (Refer to "Venting" Sections)

4)Make gas and electrical connections. Test the pilot. Must be as per diagram.

(Refer to "Gas Line Installation" and "Pilot Adjustment" Section).

Convert to Propane if desired.

(Refer to "Conversion Kit from NG to LPG" Section).

5)Install standard and optional features. Refer to the following sections:

a. Optional Brick Panels b. Log Set Installation c. Standard Flush Door d. Optional Flush Trim e. Double Screen Door

UNIT DIMENSIONS

4) The P33-4 can be installed in a recessed

position or framed out into the room as in

 

 

 

A, B, C, D. See Diagram 1 below.

5) This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6) The P33-4 Direct Vent Gas Fireplace is approved for alcove installations, which meet the clearances listed on the "Clearances" Section.

7) We recommend that you plan your installation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have a qualifi ed inspector, dealer, or installer review your plans before installation.

Note: For vent terminations see "Exterior

Vent Termination Locations" Section.

Diagram 1

f.Optional Bay Door

g.Optional Bay Trim

h.Flush Louvers

i.Bay Louvers

j.Full Screen Doors

k.Optional Wall Themostat

l.Optional Remote Control

m.Optional Wall Switch

n.Installing the Optional Fan

6)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is

ring correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

LOCATING YOUR

FIREPLACE

1)When selecting a location for your fi replace, ensure that the clearances outlined on this page are met.

2)Provide adequate clearances for servicing.

3)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete).This may be the floor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood flooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

A)Flat on Wall

B)Flat on Wall Corner

C)Recessed into Wall/Alcove

DUCT SYSTEM OPTION

kit #946-556

The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time.This includes the internal blower option as well.

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

7

Page 7
Image 7
Regency P33-LP4 Installation Checklist, Unit Dimensions, Locating Your Fireplace, Duct System Option, This includes