Regency P33R-LP2, P33R-NG2 Vertical Termination With Co-Linearflex System, Required Parts

Models: P33R-NG2 P33R-LP2

1 40
Download 40 pages 27.95 Kb
Page 16
Image 16
VERTICAL TERMINATION

INSTALLATION

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the Venting Arrangements on next page for minimum and maximum heights.

Required Parts:

Part # Description

946-529 Co-linear DV Vertical Termination Cap

948-305 3" Flex - 35 ft.

946-563 Co-Axial to Co-Linear Adapter Kit which contains the following: Co-linear Flex Adapter

Outer Pipe

Inner Pipe Adapter

510-994 Flue Adaptor

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with flashing

FPI Cabinet and/or Flat Wall Mantles may be used in these applications ensuring that clearances to com- bustibles are maintained.

Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

16

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

Page 16
Image 16
Regency P33R-LP2, P33R-NG2 installation manual Vertical Termination With Co-Linearflex System, Required Parts