OPERATING INSTRUCTIONS

COPY OF THE LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss oflife.Improperinstallation,adjustment,alteration,serviceormaintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A)This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance

-Do not touch any electric switch, do not use any phone in your building

-Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

CAUTION:Hotwhileinoperation.Donottouch.SevereBurnsmayresult.Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

LIGHTING INSTRUCTIONS

STOP! Read

the

safety information 4) Push in control knob all the way and

above on this label.

hold in. Continually push and release

1) Push in gas control knob slightly and

the black button on spark igniter until

turn clockwise

to “OFF”. Knob

pilot lights. Continue to hold the

cannotbeturnedfrom“PILOT”to“OFF”

control knob in for about 1/2 minute

unless knob is pushed in slightly. Do

after the pilot is lit. Release knob and

not force.

 

 

it will pop back up. Pilot should remain

2) Wait five (5) minutes to clear out any

lit. If it goes out, repeat steps 1) to 4).

gas. If you then smell gas STOP! follow

If knob does not pop up when released,

“B” in the safety information above on

stop and immediately call your service

this label. If you don’t smell gas, go to

technician or gas supplier. If the pilot will

the next step.

 

not stay lit after several tries, turn the gas

3) Turn knob

on gas control counter-

control knob to “OFF” and call your

clockwise

 

to“PILOT”.

service technician or gas supplier.

PILOT BURNER

VEILLEUSE

THERMOPILE

ELEMENT

THERMO-

ELECTRIQUE

OFF 5) Turn gas control knob counterclock-wise

to “ON”.

6) Use rocker switch to op- erate main burner.

TO TURN OFF GAS APPLIANCE

1)Push in the gas control knob slightly and 2) Turn off all electric power to the turn clockwiseto “OFF”. Do not force. appliance if service is to be performed.

You may shut off the pilot during prolonged non use periods to conserve fuel.

DO NOT REMOVE THIS INSTRUCTION PLATE 908-017a

28

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

Page 28
Image 28
Regency P33R-LP2, P33R-NG2 installation manual Operating Instructions, Copy of the Lighting Plate Instructions