INSTALLATION

A) 02-57

 

 

60

 

02

-

C)

B) 02-61

 

 

 

6) Place the bottom left front edge of Log D) 02-58 against the left edge of the burner tray and rest the log on the cutout on Log C) 02-60.

A) 02-57

D) 02-58

C)102

-60

B) 02-61

 

 

Cutout

8) Place the embers on the front of the burner tray in the places shown on the photo.

Place embers in these 3 locations

on the burner tray.

9) Test fire to ensure proper light off (make

 

sure flame flows smoothly from one end of

Diagram 1

burner to the other). If there is any flame

 

hesitation, check that area for any block-

 

age of the burner ports.

 

10) Install flush glass and bay glass (if used) as per instructions in this manual.

A) 02-57

 

 

 

 

 

 

 

Diagram 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D) 02-58

 

 

 

 

 

 

Use the hook to pull the spring out until you can

 

 

60

 

E)

 

 

 

 

 

02

 

put the hook into the slot on the bottom door

 

02

-

 

 

 

 

 

 

 

bracket. Repeat for 2nd spring. See diagram 3.

 

 

 

 

-

C)

 

 

B) 02-61

 

 

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7)Position Log E) 02-59 across the cutouts in Logs B) 02-61 and C) 02-60. The notch in the bottom right end fitting against the 5th grate tab.

 

 

 

 

E)

 

 

 

 

02

 

 

 

 

-

 

 

 

 

59

 

02

-

60

B) 02-61

 

 

 

C)

 

 

 

 

 

 

 

5th Grate Tab

A) 02-57

D) 02-58

 

 

60

E)

 

 

02

-

 

 

B) 02-61

02

 

C)

 

-

 

 

 

59

 

 

 

 

STANDARD FLUSH

DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

Diagram 3

To remove the flush door, reverse the above steps.

Optional Flush Trim

Attach the round magnets to the back of the top trim piece and to the bottom trim piece, then attach trim to the top and bottom of Flush door.

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

23

Page 23
Image 23