Any oxygen flow must be turned off when the flow generator is not operating, so that unused oxygen does not accumulate within the flow generator enclosure and create a risk of fire.

At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on the pressure settings, patient breathing pattern, mask, point of application and leak rate.

The technical specifications of the mask and flow generator are provided for your clinician to check that they are compatible. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the flow generator function.

Discontinue using the Mirage Quattro if you have ANY adverse reaction to any part of the mask system, and consult your physician or sleep therapist.

Refer to your flow generator manual for details on settings and operational information.

Using the Mask

Select ‘Mir Full’ or ‘Full Face’ as the mask option when using the Mirage Quattro with ResMed flow generators that have mask setting options.

Fitting the Mask

The diagrams in section A on the illustrations sheet show how the parts of the mask fit together.

The diagrams in section B show the sequence for obtaining the best fit and comfort in using your mask. Please follow these instructions carefully.

1Twist the forehead support dial to Position 24, where the forehead support is fully extended (Fig. B-1).

2Hold the mask steadily on your face (Fig. B-2) and pull the headgear over your head.

3Bringing the lower straps below your ears, clip the headgear to the lower part of the mask frame (Fig. B-3).

4Unfasten the Velcro®, pull the upper headgear straps evenly until they are comfortable and firm, and reattach the Velcro (Fig. B-4).

5Repeat step 4 with the lower headgear straps (Fig. B-5).

6Test the functioning of the valve by sealing the swivel with your hand and ensuring that you can still breathe freely.

7Connect the main air tubing to the swivel (Fig. B-6). Then connect the free end of the air tubing to your flow generator and turn the flow generator on.

2

Page 6
Image 6
ResMed 618362 manual Using the Mask, Fitting the Mask

618362 specifications

ResMed 618362 is a cutting-edge medical device designed to revolutionize respiratory therapy for patients with obstructive sleep apnea (OSA) and other respiratory disorders. As part of ResMed's reputation for innovation, this device brings together advanced technology and user-friendly features to enhance patient comfort and treatment adherence.

One of the key features of the ResMed 618362 is its Adaptive Airflow Technology. This technology allows the device to automatically adjust the pressure delivered to the patient based on their breathing patterns. By continuously monitoring the patient’s airflow, it ensures a comfortable experience throughout the night by adapting to changes in their position or sleep stage, minimizing interruptions.

The device is equipped with a sleek, lightweight design, making it highly portable and easy to use. This is particularly beneficial for patients who travel frequently or wish to use the device at different locations. The compact size does not compromise on performance; it maintains consistent pressure levels for effective therapy.

Another noteworthy characteristic of the ResMed 618362 is its Quiet Operation. The device is engineered to produce minimal noise, allowing for a more peaceful sleep environment both for the patient and their partners. This is crucial, as noise can often be a deterrent for patients adhering to their prescribed therapy.

Connectivity is also a strong feature of the ResMed 618362. The device is integrated with cloud technology, enabling healthcare providers to remotely monitor patient data in real-time. This connectivity allows for timely interventions and adjustments in therapy, improving overall treatment outcomes. Patients can also access their usage data through a user-friendly mobile app, empowering them to take an active role in managing their sleep health.

Moreover, the ResMed 618362 emphasizes user comfort with its customizable mask options. The device supports a variety of mask styles, ensuring a proper fit for different facial structures and personal preferences. This helps in reducing the chances of mask leaks and enhances treatment efficacy.

Overall, the ResMed 618362 stands out as a sophisticated solution for those suffering from sleep apnea. With its advanced adaptive technology, portability, quiet operation, and strong connectivity features, it undoubtedly promotes better health outcomes and improves the overall quality of life for users. As healthcare continues to evolve, devices like the ResMed 618362 demonstrate the importance of patient-centered design in respiratory therapy.