Attach this information to a wall near the ROBERTS GORDON® heater.

®

I n f r a r e d H e a t i n g

Read the Installation, Operation, and Service Manual thoroughly before installation, operation, or service.

Know your model number and installed configuration.

Model number and installed configuration are found on the burner and in the Installation, Operation and Service Manual.

Write the largest clearance dimensions with permanent ink according to your model number and configuration in the open spaces below.

OPERATING INSTRUCTIONS

WARNING

 

 

 

1.STOP! Read all safety instructions on this information sheet.

2.Open the manual gas valve in the heater supply line.

3.Turn on electric power to the heater.

4.Set the thermostat to desired setting.

 

TO TURN OFF THE HEATER

 

 

 

 

 

 

 

 

1. Set the thermostat to off or the lowest setting.

 

 

 

Fire Hazard

 

 

IF THE HEATER WILL NOT OPERATE, TO ENSURE YOUR SAFETY,

Some objects can catch fire or explode when placed close

FOLLOW THESE INSTRUCTIONS TO SHUT DOWN YOUR HEATER

to heater.

 

 

 

 

Keep all flammable objects, liquids and vapors the required

1. Set the thermostat to off or the lowest setting.

clearances to combustibles away from heater.

2.

Turn off electric power to the heater.

Failure to follow these instructions can result in death,

3.

Turn off the manual gas valve in the heater supply line.

4.

Call your registered installer/contractor qualified in the installation

injury or property damage.

 

and service of gas-fired heating equipment.

 

 

 

Maintain ???? cm clearance

to the side and

???? cm clearance below the heater from vehicles and combustible materials.

Roberts-Gordon, LLC

Roberts-Gordon Europe Limited

Service Telephone: +44(0) 1902 498733

1250 William Street

Oxford Street

Service Fax: +44(0) 1902 401464

P.O. Box 44

Bilston, West Midlands WV14 7EG UK

E-mail: uksales@rg-inc.com

Buffalo, NY 14240-0044 USA

Telephone: +44(0) 1902 494425

E-mail: export@rg-inc.com

Fax: +44(0) 1902 403200

 

Telephone: 716.852.4400

 

 

 

Fax: 716.852.0854

 

 

Toll Free: 800.828.7450

 

 

Installation Code and Annual Inspections:

All installations and service of ROBERTS GORDON® products must be performed by a contractor qualified in the installation and service of products sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON® products and perform service where necessary, using only ROBERTS GORDON® replacement parts.

© 2006 Roberts-Gordon, LLC

All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photocopying,

 

recording, taping, or information storage and retrieval systems – without written permission of Roberts-Gordon, LLC.

 

www.rg-inc.com

Printed in U.S.A.

P/N 91037912 Rev. C

Page 72
Image 72
Roberts Gorden CRV-B-8, CRV-B-9, CRV-B-12A, CRV-B-6, CRV-B-10, CRV-B-2, CRV-B-4 service manual F r a r e d H e a t i n g

CRV-B-4, CRV-B-12, CRV-B-2, CRV-B-10, CRV-B-6 specifications

The Roberts Gordon CRV-B-9 is a state-of-the-art infrared radiant heater designed for industrial and commercial heating applications. Renowned for its efficiency and effectiveness, the CRV-B-9 represents a significant advancement in the world of space heating solutions.

One of the main features of the CRV-B-9 is its advanced infrared technology, which allows for precise heating without the necessity of warming the entire space. This targeted heating provides immediate comfort, as it directly warms objects and people rather than the air around them, making it particularly effective in large warehouses, manufacturing facilities, and retail spaces.

The heater boasts an impressive output of up to 80,000 BTUs, making it suitable for a wide range of applications. It utilizes natural gas as fuel, which contributes to its efficiency and cost-effectiveness. With a robust design and durable construction, the CRV-B-9 is built to withstand the rigors of industrial environments while ensuring a long product lifespan.

Another significant characteristic of the CRV-B-9 is its ability to integrate with advanced control systems. This includes compatibility with programmable thermostats and energy management systems, allowing for optimized temperature control and reduced energy consumption. The heater can be adjusted to suit different operational needs, making it a flexible solution for various heating scenarios.

The CRV-B-9 also features a compact design, allowing for easy installation in a variety of spaces. Its low-profile shape and modular capability enable users to arrange multiple units to achieve the desired heating coverage without compromising floor space, a crucial aspect for busy, high-traffic areas.

Safety is a priority with the CRV-B-9, which is equipped with various safety features such as a flame safety cutoff switch and over-temperature protection. These mechanisms ensure safe operation, providing peace of mind for users in demanding environments.

In summary, the Roberts Gordon CRV-B-9 infrared radiant heater stands out for its innovative technology, impressive output, energy efficiency, and safety features. Its flexibility and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy costs. Whether in a manufacturing plant or a retail outlet, the CRV-B-9 provides a reliable and effective heating solution.