SECTION 17: GENERAL SPECIFICATIONS
General Specifications for pumps are as follows:
Pump Dimensional Data (in.) |
|
|
|
|
|
|
|
| ||
Model | A | B | C | D | E | F | G |
|
|
|
17 | 14.5 | 21 | 3.75 | 10 | 4 | 4 | A | G |
| |
17.75 | 17 | 20.25 | 3.25 | 10 | 4.5 | 4.5 |
|
|
| |
25.6 | 24.8 | 22.7 | 4.8 | 15.2 | 6 | 6 |
| D | E | |
|
|
|
|
|
|
|
|
| B |
|
|
|
|
|
|
|
|
|
| C | F dia. |
|
|
|
|
|
|
|
|
|
|
Pump Specifications
Model |
|
|
|
|
|
|
|
|
|
|
|
Horsepower (Hp) | 1/3 | 3/4 | 3/4 | 2* | 2* |
|
|
|
|
|
|
Phase (Ø) | 1 | 1 | 3 | 1 | 3 |
|
|
|
|
|
|
Hertz (Hz) | 60 | 60 | 60 | 60 | 60 |
|
|
|
|
|
|
Voltage (V) | 115/230 | 115/230 | |||
|
|
|
|
|
|
Full Load Amp (Amps) | 4.8/2.4 | 6.6/3.3 | |||
|
|
|
|
|
|
R.P.M. | 3450 | 3450 | 3500 | 3450 | 3450 |
|
|
|
|
|
|
Motor Frame | 56 | 56 | 56 | 90 | 90 |
|
|
|
|
|
|
Motor Enclosure | TENV | TENV | TEFC | TEFC | TEFC |
|
|
|
|
|
|
Noise Level @ 5' (DBA) | - | 70 | 70 | - | - |
|
|
|
|
|
|
Inlet/Outlet (In.) | 4/4 | 4/4 | 4/4 | 6/6 | 6/6 |
|
|
|
|
|
|
Weight (lbs.) | 62 | 112 | 112 | 170 | 170 |
|
|
|
|
|
|
* For starter, see National Electric Code (NEC) requirement for motors 1 hp or higher.
Air Supply Blower Specifications
Capacity | 240 CFM @ 0.75 in wc |
|
|
Power (W) | 167 |
|
|
Phase | 1 |
|
|
Hertz (Hz) | 60 |
|
|
Voltage (V) | 120 |
|
|
Full Load Amp (Amps) | 1.5 |
|
|
R.P.M. | 3000 |
|
|
Motor Enclosure | OPEN FC |
|
|
Inlet/Outlet (In.) | 5/5 |
|
|
Weight (lbs.) | 10 |
59