SECTION 7: HEATER INSTALLATION
SECTION 7: HEATER INSTALLATION
WARNING
Suspension Hazard
Hang heater with materials with a minimum working load of 75 lbs (33 kg).
Failure of the supports can result in death, injury or property damage.
To ensure your safety and comply with the terms of the warranty, all units must be installed in accordance with these instructions.
The gas or the electrical supply lines must not be used to support the heater.
FIGURE 12: Critical Hanger Placement
Do not locate the gas or electric supply lines directly over the path of the flue products from the heater. The heater must be installed in a location that is readily accessible for servicing.
The heaters must be installed in accordance with clearances to combustibles as indicated on the rating plate and in this instruction manual.
The minimum and maximum gas inlet pressures must be maintained as indicated on the rating plate. Typical installation configurations are shown in Figure 12.
Expansion and contraction of the tube dictates that the minimum suspension lengths in the table on Figure 12 be maintained.
Typical Suspension Details
Beam Clamp
Anchor
Screw Hook 3/8"
|
| Chain size |
| Rod 3/8" | 3/16" minimum |
|
| |
24" min. |
|
|
(61 cm) | "X" (See Table) |
|
| Turnbuckle | |
|
|
Locknut (Typical)
Concrete Beam
Wood Beam
Locknut
Washers
7'6" (2.3 m)
|
|
| Turnbuckle |
|
|
|
| Hanger |
|
|
|
| Reflector |
|
| Side View | Towards Pump | Front View | |
|
| Run Length | Typical Expansion | Minimum “X” Length |
|
| 50' (15 m) | ±1" (3 cm) | 12" (30 cm) |
Description | Part Number | 100' (31 m) | ±2" (5 cm) | 24" (61 cm) |
Turnbuckle | 91903201 | 150' (46 m) | ±3" (8 cm) | 36" (91 cm) |
91907302 | 200' (61 m) | ±4" (10 cm) | 46" (122 cm) | |
Tube/Reflector Hanger | 03090100 | 250' (76 m) | ±5" (13 cm) | 57" (145 cm) |
15