Section 2: Installation & Programming
21822666 2-29
IR VOLUME CONTROL 2CH PREAMP
Volume can be controlled by a 21958307 IR transmitter and a single- or dual-wired remote control.
When the wired volume control is moved, the volume will quickly fade up or down to match its position. When moving
a wired remote control, it is best to quickly turn the volume off then turn it up to the desired volume. This will eliminate
a sudden loud blast if the wired remote control was set at or close to full volume.
The IR transmitter Ch1+, Ch2+, Ch1-, Ch2- keys will raise and lower the volume.
The ROWELINK RCB LED should flash continuously at approximated 20 CPS.
The IR VOL COMM LED will flash when a Ch1+, Ch2+, Ch1-, Ch2- key is pushed.
Single Volume Control Setup
Set terminal block jumper as shown in Figure 2-8A Remote Volume & Cancel Control 30632201.
On 40933101 set all S1 DIP switches to OFF (refer to Figure 2-8B).
On 40933101 plug connector into P2. P1 is left open.
Dual Volume Control Setup
Set terminal block jumper as shown in Figure 2-8A Dual Remote Volume & Cancel Control 30632209.
On 40933101 set S1-1 DIP switch to ON and all others OFF (refer to Figure 2-8B).
On 40933101 plug connector into P1. P2 is left open.
Figure 2-8B. IR Volume Control 2CH Preamp