Runco CL-810 CINEWIDE, CL-810 ULTRA RS-232 Controller, 14. RS-232 Control System Connection

Models: CL-810 / SDC-1 CL-810 ULTRA CL-810 CINEWIDE

1 92
Download 92 pages 44.57 Kb
Page 42
Image 42
RS-232 Controller

Installation

RS-232 Controller

Connect a PC or home theater control/automation system (if present) to the RS-232 port

Connection

 

on the CL-810; see Figure 3-14.Use a standard, 4-wire RJ-11 telephone cable, wired

 

 

straight-through.

 

 

For more information about using this connection, refer to Serial Communications on

 

 

page 69.

S-VID /

VID-S

RJ-11 Male

Yellow

Green

1

 

2

Black

3

4Red

RJ-11 to D-Sub 9-pin Adapter (not included)

Yellow

 

 

 

 

 

Green

 

 

 

 

 

 

5

4

3

2

1

Black

9

8

 

7

6

 

 

 

 

 

Red

D-Sub 9-pin female

RS-232 Adapter Wiring

D-Sub 9-pin female

4-pin RJ-11

Function

 

 

 

2

2

Transmit Data

 

 

 

3

3

Receive Data

 

 

 

5

1, 4

Ground

 

 

 

1, 4, 6, 7, 8, 9

--

Not Connected

 

 

 

Figure 3-14. RS-232 Control System Connection