Testing operations
7.DIP switch option
ON
1 2 3 4
SW507
ON
1 2 3 4
SW508
ffDIP switch(SW507) option
| On (default) | Off | |
Switch 1 | Auto address | Manual address | |
Switch 2 | Disable snow prevention control | Enable snow prevention control | |
Switch 3 | Silence Mode option | ||
Switch 4 | |||
|
|
❋❋When snow prevention mode is in use, eco mode(standby mode)will not be functional.
❋❋When DPM installation is applied, the time for auto addressing will take 1~2minutes.
During the addressing, and will be repeatedly displayed in order for 2 indoor unit connection,, and for 3 indoor unit connection,,, and for 4 indoor unit connection.
When addressing is completed,,,, and will be repeatedly displayed in order for 2 indoor unit
connection,,,,, and for 3 indoor unit connection,,,,,,
and for 4 indoor unit connection.
ffDIP switch(SW508) option
| On(default) | Off |
Switch 1 | Auto Silence Mode | Manual Silence Mode |
Switch 2 | - | - |
Switch 3 | - | - |
Switch 4 | - | - |
8.Silence Mode DIP switch option ffDIP switch(SW507) option
Switch 3 | Switch 4 | Operation |
On | On | Disable Silence mode |
On | Off | Silence mode 1st step |
Off | On | Silence mode 2nd step |
Off | Off | Silence mode 3rd step |
ENGLISH-64
PAC MIRAGE