There must be no space between the terminal and the screw when connected.
The terminal socket
is upside down. or there is a space between the screw and the ring terminal.
• For the terminal block wiring, use a wire with a ring terminal socket only.
CAUTION | ng work. |
When you install the unit, make refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled,
disconnect electrical cables, then refrigerant connections.
If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.
The maximum length of the cable is 15(** 10/13 ** )/ 30( ** 18/24 ** ) meters.
1. Extend the assembly cable if necessary.
•Do not connect two or more cables to extend the length.
It may cause
2 . Open the front grille.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)
• Each wire is labeled with the corresponding terminal number.
5 . Pass the other end of the cable through the 65mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the front grille.
8 . Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture.
ENGLISH
Indoor unit | 18/24 |
10/13 | |
Indoor unit | Indoor unit |
Outdoor unit |
|
Outdoor unit |
|
| Outdoor unit F1 F2 |
* |
|
F1 F2
F1 | F2 |
• Also circular terminal must be matched with screw size in terminal block.
• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.
10.Connect the grounding conductor to the grounding terminals.
11.Close the terminal board cover by tightening the screw carefully.
• In Russia and Europe, consult with the supply authority to determine the supply system impedance before
| installation. |
|
• | Connect the wires according to color codes, referring to the wiring diagram. |
|
• | The power cable and the interconnection cable should be selected according to the | in page 28. |