Samsung ASV18PUQXXEA Fixing the outdoor unit in place, Outdoor unit installed on the wall by rack

Models: ASV18PUQXXEA ASV10PUQNXEA ASV18PSPXXEA ASV10PUQXXEA ASV24PUQNXEA ASV18PUQNXEA ASV24PUQXXEA ASV13PSPXXEA ASV10PSPXXEA ASV13PSPNXEA ASV18PSPNXEA ASV24PSPNXEA ASV13PUQNXEA ASV10PSPNXEA ASV24PSPXXEA ASV13PUQXXEA

1 41
Download 41 pages 41.26 Kb
Page 38
Image 38

Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priorly.

After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate.

1.

part without insulation on the end of the pipes.

2.Wind the pipe, assembly cable and drain hose with vinyl tape.

3.Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.

4.Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

Make sure pipe does not move when you install the indoor unit on

an installation plate.

5.Wrap the rest of the pipe with vinyl tape.

6.Attach the pipe to the wall using clamps (optional).

Insulation

Pipes

 

Installation

 

plate

Connecting

Vinyl tape

pipes

Connecting wires

 

Drain hose

 

Fixing the outdoor unit in place

Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

appropriate support (wall or ground).

'X' mm

'Y' mm

1.

Place the outdoor unit as indicated on the top of the unit to let the discharged air out

 

 

 

 

Rubber leg

 

 

 

 

 

 

 

 

 

properly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

X

Y

2.

Fix the outdoor unit in level to an appropriate support using anchor bolts.

 

10/13

538

290

3.

If the outdoor unit is exposed to strong winds, install shield plates around the outdoor

 

 

 

18

543

319

 

 

 

24

660

340

 

unit so that the fan can operate correctly.

 

 

 

• Secure the rubber leg to prevent the generation of noise and vibration.

Outdoor unit installed on the wall by rack

Designed to cut o residual vibration

from outdoor unit to rack.

 

 

(not supplied with product)

• Ensure the wall will be able to suspend the weight of rack and outdoor unit;

Install the rack close to the column as much as possible;

• Install proper grommet in order to reduce noise and residual vibration transferred by outdoor unit towards wall.

Soft rubber designed to cut vibration from rack to wall. (not supplied with product)

38

Page 38
Image 38
Samsung ASV18PUQXXEA manual Fixing the outdoor unit in place, Outdoor unit installed on the wall by rack, Properly Model