PIP On/Off control

•• Function

The PIP mode of a product can be turned on or off using a PC. ――Only available on models that have the PIP function. ――This function is not available in MagicInfo.

•• Viewing PIP on/off state (Get the PIP ON / OFF Status)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

0x3C

 

0

 

•• Setting PIP on/off (Set the PIP ON / OFF)

Header

Command

ID

Data length

Data

Checksum

 

 

 

 

 

 

0xAA

0x3C

 

1

"PIP"

 

"PIP": A code used to turn the PIP mode of a product on or off

1:PIP ON

0:PIP OFF

•• Ack

Header

Command

ID

Data

Ack/Nak

r-CMD

Val1

 

Checksum

 

 

 

 

length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

 

3

'A'

0x3C

"PIP"

 

 

 

 

 

 

 

 

 

 

"PIP": A code used to turn the PIP mode of a product on or off

 

 

 

 

•• Nak

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Command

ID

Data

Ack/Nak

r-CMD

Val1

 

Checksum

 

 

 

 

length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

 

3

'A'

0x3C

"PIP"

 

 

 

"ERR": A code showing what error has occurred

Auto adjustment control (PC and BNC only)

•• Function

Automatically adjust the PC system screen using a PC.

•• Viewing auto adjustment state (Get Auto Adjustment Status) None

•• Setting auto adjustment (Set Auto Adjustment)

Header

Command

ID

Data length

Data

Checksum

 

 

 

 

 

 

0xAA

0x3D

 

1

"Auto

 

 

 

 

 

Adjustment"

 

"Auto Adjustment" : 0x00 (at all times)

•• Ack

Header

Command

ID

Data

Ack/Nak

r-CMD

Val1

Checksum

 

 

 

length

 

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

 

3

'A'

0x3D

"Auto

 

 

 

 

 

 

 

Adjustment"

 

 

 

 

 

 

 

 

 

•• Nak

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Command

ID

Data

Ack/Nak

r-CMD

Val1

Checksum

 

 

 

length

 

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

 

3

'A'

0x3D

"ERR"

 

"ERR": A code showing what error has occurred

34

Page 34
Image 34