Setup Tool

Title

Enter the title of the Email.

Message

Enter the contents of the Email. An alarm image is attached to the Email as an attached file.

Test

To test SMTP transmission, Click [Test] button. Connect to the configured SMTP server and conduct image transmission test automatically. When the SMTP server connection and transmission tests are complete, the <Verified> message will be displayed.

If the test fails, an error message appears. In this case, check the SMTP server status and the configured settings once again.

ALARM IMAGE SETUP

Transfer Mode

You can select a method to send an alarm image from the <FTP>, <E-Mail>.

<FTP Transfer>: The image is sent to the specified FTP address.

<E-Mail Transfer>: The image is sent to the specified Email address.

Transferred Image Naming Setup

You can set the file name of an alarm image to be sent when an alarm is generated or during the scheduled transfer.

Pre/Post Alarm Image

You can determine which of previous or posterior image is to be sent.

<Number of Image>: Determines number of images to be sent per second. You can select 1, 2, 3 and 5 images per second.

<Pre-Alarm Duration>: Determines time of prior images to be sent. You can select one from <5 sec>, <10 sec>, <15 sec> and <30 sec>. You can send a prior image of up to 30 seconds after an alarm is generated. (The maximum time is determined by the number of images to be sent per second.)

<Post-Alarm Duration>: Determines time of posterior images to be sent. You can select one from <5 sec>, <10 sec>, <15 sec> and <30 sec>. You can send a posterior image of up to 30 seconds after an alarm is generated. (The maximum time is determined by the number of images to be sent per second.)

ALARM INPUT SETUP

Various functions of 8 Alarm Inputs can be set up independently.

Input Device Setup

Select an input type from the <OFF>, <NO> and <NC>.

<NO>(Normal Open): It is normally open, but if it is close, an alarm will be generated.

<NC>(Normal Close): It is normally close, but if it is open, an alarm will be generated.

Activation Time

You can set time to accept an alarm to take an action.

<Always>: Always conducts the <Action> setting when an alarm is generated.

<Only Scheduled Time>: Conducts the <Action> setting for an alarm only when it occurs during the specified time period on the specified day of the week. The Start Time must prior to and must differ from the End Time.

Action

You can set an operation to be conducted when an alarm is generated.

<Alarm Output>: Determines alarm output port to which the alarm signal is to be sent.

<Output Duration>: Determines the period of time to output alarm signal to the specified alarm output port when an alarm is generated. If another alarm event is generated during the alarm output, the delay time is recalculated on the basis of the most recently generated an alarm.

<Alarm Image Transfer>: If <On> is selected, a JPG image is transmitted through FTP or

46 – 36x IP Smart Dome Camera