ALARM RECORDING

By connecting the ALARM IN terminal to a door switch, an interphone, etc., a recording can be done only when necessary.

Alarm Recording Setting

Alarm recording is performed when there is an input (trigger) at the ALARM IN terminal, “AL” is displayed on the digital display.

1Make all necessary connections.

2Press the AUDIO ON/MENU button until the (SET UP 3) menu is displayed.

°The “ALARM MODE” setting is flashing.

<SET UP 3>

 

ALARM MODE

Y1

ALARM SPEED

3H

ALARM DURATION

20S

TAPE IN MODE

STOP

TAPE END MODE

REW

TAPE END OUT

-3M

CLOG DETECT.

Y

3Press the l (or j) button to set the desired alarm mode, then press the ] button.

Y1 . . . . . . Alarm recording is done when there is an alarm trigger.

Y2 . . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording.

Y3 . . . . . . Alarm recording is done only if there is an alarm trigger and the VCR is not in programmed timer recording mode.

N . . . . . . . Alarm recording is not performed even

if there is an alarm trigger.

4Press the l (or j) button, to set the desired alarm recording speed, then press the ] button.

3H . . . . . . 3-hour mode recording

12H . . . . . 12-hour mode recording

NC . . . . . Recording at the speed already set

5Press the l (or j) button, to select the desired alarm recording duration (20S, 40S, 1M, 2M, 3M, 5M, CC or TRIG).

20S-5M. . Recording only for the displayed duration

CC. . . . . Recording as long as the alarm signal is being input (minimum recording of 5 seconds)

TRIG. . . . Will switch between recording pause and recording every time an alarm trigger is received during recording

6Press the PAUSE/SCAN button, the normal screen is displayed.

° The setting procedure is now completed.

GB

 

NOTES:

During alarm recording all buttons are disabled.

If “OFF” is displayed on the digital display, alarm recording is not possible in order to prevent the recorded tape to be recorded over.

To cancel the “OFF” display, press the EJECT, PLAY, STOP, FF or REW button.

If an alarm trigger is received while alarm recording is in progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan search.

If there is a power failure during alarm recording, and the power is restored within the recording set duration, alarm recording will continue.

If the alarm scan function will be used to review the recordings, set the recording speed to 3-hour mode and the recording duration to 20 seconds or more.

14

English

Page 15
Image 15
Sanyo TLS-224P instruction manual Alarm Recording Setting