ALARM RECORDING

Alarm Recording Counter Display

During alarm recording, “AL” will be flashing on the digital display.

If the ON SCREEN switch is set to the “ON” position, the number of alarms will flash on the monitor screen.

The maximum display number of alarm triggers is “999”, at the next alarm recording the counter will indicate “000”.

When the (ALARM TIME) menu is displayed, press the MENU RESET button to reset the alarm counter to “000” (all the data of the (ALARM TIME) menu is reset).

GB

Connections to the ALARM IN/OUT

 

 

Terminals

 

Alarm input signal

 

Connect a make-contact (no voltage) switch between

 

the ALARM IN and COM terminals.

 

Alarm output signal

 

Normally DC 5V are output between the ALARM

 

OUT and the COM terminals. When an alarm input

 

(trigger) is received and the unit is recording, the

 

output falls to 0V. Once the alarm recording is over,

 

the output returns to DC 5V.

Checking the Alarm Recordings Time

1Press the AUDIO ON/MENU button until the (ALARM TIME) menu is displayed.

°The number of alarm triggers, and the 8 most recent alarm recording times are displayed.

Example

<ALARM TIME> 008 12-12 19:00 12-11 23:00 12-11 15:00 11-10 08:00 11-10 06:00 10-09 20:00 10-09 16:35 10-09 10:52

NOTE:

The data for the previous alarm recordings is erased.

2Press the PAUSE/SCAN button, the normal screen is displayed.

NOTE:

If the MENU RESET button is pressed while the (ALARM TIME) menu is displayed, the displayed data is erased.

“AL” will be erased from the digital display.