Scotsman Ice C0522, C0530, C0830, C1030, C0630 Remote condenser, Exterior Panels, Water filters

Models: C0630 C1030 C0830 C0530 C0522

1 28
Download 28 pages 53.84 Kb
Page 25
Image 25
Remote condenser

C0522 through C1030

Remote Condenser Models - User Manual

Remote condenser

The condenser fins will need to be cleaned.

Push and release the Off button. Wait until the machine stops.

Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart.

If there is imbedded grease, use a commercial coil cleaner to wash out the grease. Dust can be blown out with compressed air from the inside or use a vacuum cleaner and soft brush. Be careful not to damage the condenser’s fins. Use a fin comb to straighten any bent fins.

Exterior Panels

The front and side panels are durable stainless steel. Fingerprints, dust and grease will require cleaning with a good quality stainless steel cleaner. The top panel is plastic, wipe it off with a damp cloth to remove dust and dirt.

Water filters

If the machine has been connected to water filters, check the cartridges for the date they were replaced or for the pressure on the gauge. Change cartridges if they’ve been installed more than 6 months or if the pressure drops too much when the ice machine fills with water.

July 2006