Adjustments
Bridge Thickness - For the Service Tech Only
1.Push and hold Off till the machine stops.
2.Remove evaporator cover.
3.Remove curtain.
4.Use a hex wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness. Rotate CCW to decrease bridge thickness.
Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments are not covered by warranty.
C0522 through C1030 Remote Condenser Models - User Manual
1/8 - 3/16" bridge
Too Big | Just Right, | Just Right, | Too Small |
| small cube | med cube |
|
Ice Bridge Thickness Check
5.Return curtain and evaporator cover to their normal positions.
6.Push and release the On button. Check next
harvest of ice. Repeat steps
Water Purge Setting
The water purge is factory set to automatically |
|
|
| ||||
adjust the amount of water purged per cycle. The |
|
|
| ||||
setting can be changed to one of 5 manual settings |
|
|
| ||||
or left on automatic. |
|
| Bridge Thickness Adjustment Mechanism | ||||
Purge | 1 - Minimum | 2 - | 3 - | 4 - Heavy | 5 - Maximum | A - Automatic | |
setting | Moderate | Standard | |||||
|
|
|
| ||||
|
|
|
|
|
| Factory setting, | |
| RO water or | Low TDS | Setting for |
| Very High | suitable for any | |
Water | equivalent, | High TDS | TDS water, | water with | |||
non - RO | typical | ||||||
Type | TDS less than | water | greater than | conductivity not | |||
water | water | ||||||
| 35 |
| 256 | less than 10 | |||
|
|
|
| ||||
|
|
|
|
|
| microSiemens/cm. |
To set:
1.Switch the machine OFF by holding the Off button in until a number or the letter A shows on the display.
2.Press and release the On button repeatedly until the number on the display corresponds to the desired setting.
3.Press and release the Off switch again to return to the normal control state.