C0522 through C1030
Remote Condenser Models - User Manual
Electrical
The machine is not supplied with a power cord, one must either be field installed or the machine
The dataplate on the back of the cabinet details the power requirements, including voltage, phase, minimum circuit ampacity and maximum fuse size. HACR type circuit breakers may be used in place of fuses. Extension cords are not permitted. Use of a licensed electrician is recommended.
The ice maker is designed to operate on its own electrical circuit and must be individually fused. Voltage variation must not exceed the limits listed earlier.
The remote condenser is designed to be powered from the ice machine. A separate knockout hole has been provided in the ice maker electrical junction box.
Electrical connections are made inside the junction box in the back panel of the ice machine.
1.Remove the junction box cover and route the power cord through the access hole and properly attach the power supply wires to the leads in the junction box.
2.Attach the remote condenser fan motor wires to the wires in the junction box tagged “fan motor leads”.
3.Install field supplied strain reliefs per code. Attach a ground wire to the ground connection in the junction box.
4.Check voltage when complete.
5.Return the junction box cover to its original position and secure with the original screws.
Follow all applicable local, state and national codes.
To Remote
Condenser
Fan Motor
| Install |
| Strain |
| Relief |
Junction |
|
Box |
|
Cover | Ground Wire |
| Connection |
| Install |
Power Supply | Strain |
Wires | Relief |
Electrical Connection Detail
July 2006