C0522 through C1030
Remote Condenser Models - User Manual
Product Description and Electrical Requirements
Dimensions | Model | Electrical | Use condenser | Minimum Circuit | Maximum | |
w” x d” x h” | Ampacity | Fuse Size* | ||||
|
|
| ||||
22.75*** x 24 x 23 | 115/60/1 | 14.9 | 15 | |||
same | same | same | 14.9 | 15 | ||
30.75*** x 24 x 23 | 115/60/1 | 14.9 | 15 | |||
|
|
|
|
|
| |
same | same | same | 14.9 | 15 | ||
same | 18 | 20 | ||||
30.75*** x 24 x 29 | 10 | 15 | ||||
same | 8.2 | 15 | ||||
same | 15.6 | 20 | ||||
same | 10.8 | 15 | ||||
|
|
|
|
|
|
*Or HACR circuit breakers.
**ERC211 has two circuits, when two C0522s or C0530s are connected to it, fan motor relay kit KCMR120 must be used to control the fan motor.
***Maximum width at top panel.
Ratings include the remote condenser motor, as it is designed to be powered by the ice machine. If connecting remote condenser independently of the ice machine, use the information on the condenser's dataplate for fuse and wire sizes.
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision code omitted. All the listed condensers include a headmaster valve.
Central Condenser Coils
The ice machine may be connected to a central condenser coil. The requirements are:
•Coil – not previously used with mineral oil system. Virgin coil preferred.
•Correct size (internal volume) and capacity (BTUH).
•Includes a headmaster valve for discharge pressure control. Headmaster kit available for certain MAC condensers, kit number is RCKCME6GX.
•Fan motor on all the time or controlled to be on whenever the ice machine is operating.
Precharged tubing kits:
The ice making head’s and the remote condenser’s refrigeration circuits must be connected. They are designed to be connected using precharged refrigerant tubing, supplied in kits of liquid and discharge tubes. Several lengths are available, order the one that just exceeds the length needed for the site.
10” | 20’ | 40’ | 75’ |
RTE10 | RTE20 | RTE40 | RTE75 |
|
|
|
|
|
|
|
|
No additional refrigerant is required.
Note: Refrigerant charge is supplied with the ice machine.