C0522 through C1030
Remote Condenser Models - User Manual
Installation: Product Specifications
Location Limitations | Power Supply |
This ice system is made up of three parts, the ice making machine, or head; the remote condenser; and the interconnecting tubing. The ice making machine must be installed indoors, in a controlled environment. Space must be provided near the machine for service access. The remote condenser may be installed above or below the ice machine, per the limits stated later in this manual. The remote condenser may be installed outdoors within the temperature limits listed below. The interconnecting tubing must be installed per the directions stated in this manual, and the amount of tubing exposed to uncontrolled temperatures must be minimized.
Space Limitations
Although the machine will function with no clearance to the top and sides, some space must be allowed for service access. Building the machine in with no access will cause higher service cost, in many cases this extra cost may not be covered by warranty.
Environmental Limitations, ice machine:
| Minimum | Maximum |
Air temperature | 50oF. | 100oF. |
Water | 40oF. | 100oF. |
temperature |
|
|
Water Pressure | 20 psi | 80 psi |
|
|
|
Environmental Limitations, remote condenser
| Minimum | Maximum | |
115 volt model | 104 volts | 126 volts | |
|
|
| |
198 volts | 253 volts | ||
model | |||
|
| ||
|
|
| |
|
|
|
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material and workmanship. It does not cover maintenance, corrections to installations, or situations when the ice machine is operated in circumstances that exceed the limitations printed above.
Product Information
The machine is a specialized version of a modular cuber. A modular cuber does not include any ice storage, it is designed to be placed onto an ice storage bin or ice dispenser. Many installations only require the matching bin, but some will need an adapter to be placed between the ice machine and the bin or dispenser. Additionally, the machine must be connected to the correct remote condenser and use the correct
This product cannot be stacked. See the chart for application information.
| Minimum | Maximum |
Air temperature | 120oF. | |
|
|
|
July 2006
Page 2