CME1356R and CME1656R
Service Diagnosis
Problem or Symptom | Possible Cause | Probable Correction | |
|
|
| |
|
| Check bin controls. If the bin full light is on or | |
|
| blinking the bin controls may be dirty. Clean if | |
|
| dirty. The board and bin controls may also | |
| Bin controls did not sense | need to be checked. | |
| ice falling, unit stayed in |
| |
| Check evaporators for lime scale build up. | ||
| harvest until the maximum | ||
| Clean evaporators and bin controls if dirty. | ||
| harvest time ran out. | ||
Unit is off because of a | Push and release Off button. Push and | ||
| |||
“Harvest Problem” |
| ||
| release Freeze button. Check machine | ||
|
| ||
|
| operation. Check if ice is made and harvests. | |
| Bin controls or AutoIQ | See “Unit does not shut off” below.. | |
| Controller may have failed. | ||
|
| ||
|
|
| |
| Other components may | Check the next page | |
| have failed | ||
|
| ||
|
|
| |
| Cube size control float is | Check/clean | |
| sticking. | ||
Cubes are too large |
| ||
|
| ||
Inlet water valve leaking | Check hose from water valve for slow drip. | ||
| |||
| thru (slowly) | Replace valve if dripping. | |
|
|
| |
Cubes are too small | Not enough water | Check for leak in reservoir | |
| |||
Check for a leak thru the purge valve | |||
|
| ||
| Dirty condenser | Clean condenser | |
| Recirculation of air | Block air | |
|
| Check system. If there is a low charge, find | |
Low ice capacity | Low refrigerant charge | the leak, recover the refrigerant, repair the | |
| leak, replace the dryer, evacuate and weigh in | ||
|
| ||
|
| the nameplate charge. | |
|
|
| |
| Too much water | Check for inlet water valve leak thru | |
|
|
| |
|
| Check controls. Unplug thermostat and check | |
|
| bin full light, if off, place something between | |
|
| the electric eyes. The bin full light should | |
|
| begin to blink (after 20 seconds of continuous | |
|
| blockage it will glow steadily). If not, check | |
|
| operation of electric eyes by unplugging #4 | |
|
| and jumping out the two pins on the controller | |
Unit does not shut off | Ice sensing system may | (touch the tool to the cabinet to discharge | |
have failed. | static electricity before contacting the | ||
| |||
|
| controller). If the bin full light blinks, replace | |
|
| the bin controls. If it does not blink, replace | |
|
| the controller. Note: Leaving #4 unplugged | |
|
| and jumped for 20 seconds will shut the | |
|
| machine down on a bin full (at the end of the | |
|
| harvest cycle). It will restart after 4 minutes or | |
|
| may be reset by pushing the Freeze button. | |
|
|
|