Scotsman Ice CME1356R and CME1656R, Service Diagnosis Components, Problem or Symptom

Models: CME1656R CME1356R

1 47
Download 47 pages 16.42 Kb
Page 33
Image 33
Service Diagnosis: Components

CME1356R and CME1656R

Service Diagnosis: Components

Problem or Symptom

Possible Cause

Probable Correction

 

 

 

Fan motor does not

Open motor windings, or

Replace fan motor

seized bearings

turn.

 

 

 

No power to fan motor

Contactor may not close.

 

 

Open motor windings, or

Replace pump

 

seized bearings

Pump motor does not

 

 

Check electrical connections. In Freeze, the

turn

 

No power to pump

pump should have power to it. If not, replace

 

 

 

the AutoIQ Controller.

 

 

 

 

Open solenoid coil.

Replace hot gas valve

 

 

 

Hot Gas Valve does

Stuck valve

Replace hot gas valve

not open.

 

 

 

Check wire connections, if ok, replace AutoIQ

 

No power to coil in Harvest

 

Controller

 

 

 

 

 

Hot Gas Valve leaks

 

 

thru (warm tube

Mechanical problem in

 

temperatures on both

Replace valve

valve

sides of valve during

 

 

 

freeze)

 

 

 

Open solenoid coil

Replace valve

Water Inlet Valve does

Stuck valve

Replace valve

 

 

No power to valve (best

 

not open

Check wire connections, if ok, replace AutoIQ

 

checked at the beginning

 

Controller

 

of Freeze)

 

 

 

 

 

Water Inlet Valve does

Restriction in water supply

Check water filters and/or inlet screen.

not flow enough water

 

 

 

 

 

Water Inlet Valve

Mechanical problem in

Replace valve

leaks thru

valve

 

 

 

 

 

Unit in Clean cycle

Push and release Freeze button.

 

 

 

 

Contactor coil open

Replace contactor

Compressor does not

Open starting components

Check and replace

work

Open windings

Check and replace compressor

 

 

Internal valve failure

Replace compressor

 

 

 

 

 

 

May 2001

Page 33

Page 33