CME1356R and CME1656R

Operational Characteristics: CME1656R

Cycle Times (minutes):

 

70oF. condenser air 70oF. indoor

90oF. condenser air 90oF. indoor

 

air, 50oF. water

air, 70oF. water

Freeze

15 ½ - 17 ½

18 - 19

 

 

 

Harvest

2 ½

2 ½

 

 

 

 

 

 

System Pressures (PSIG):

 

70oF. condenser air 70oF. indoor

90oF. condenser air 90oF. indoor

 

air, 55oF. water

air, 70oF. water

Suction: End of Freeze

30 - 32

33

- 35

 

 

 

 

Suction: Peak in Harvest

75 - 85

90

- 100

 

 

 

Discharge: 5 minutes into Freeze

230 - 250

275 - 295

 

 

 

Discharge: Minimum in Harvest

100

110

 

 

 

 

 

 

 

 

Number of Evaporators:

￿6

Refrigerant Charge

￿288 ounces of R-404A

Typical Compressor Amps, single phase

￿freeze 15 - 16

￿harvest 22 - 23

Typical Compressor Amps, three phase

￿freeze 9 - 10

￿harvest 13 - 14

Typical Harvest Ice Weight

￿19.2 lb.

Superheat

￿The TXV will control a nominal superheat point that can vary unit to unit from 11oF. to 17oF.

While controlling that point the superheat can also range + or - 4oF. without affecting performance.

Hi Pressure Control - Automatic Reset

￿Hi Pressure Cut Out - 450 PSIG

￿Hi Pressure Cut In - 350 PSIG

Headmaster Valve

￿Setting is 240 PSIG