CME1356R and CME1656R
Operational Characteristics: CME1656R
Cycle Times (minutes):
  | 70oF. condenser air 70oF. indoor  | 90oF. condenser air 90oF. indoor  | 
  | air, 50oF. water  | air, 70oF. water  | 
Freeze  | 15 ½ - 17 ½  | 18 - 19  | 
  | 
  | 
  | 
Harvest  | 2 ½  | 2 ½  | 
  | 
  | 
  | 
  | 
  | 
  | 
System Pressures (PSIG):
  | 70oF. condenser air 70oF. indoor  | 90oF. condenser air 90oF. indoor  | |
  | air, 55oF. water  | air, 70oF. water  | |
Suction: End of Freeze  | 30 - 32  | 33  | - 35  | 
  | 
  | 
  | 
  | 
Suction: Peak in Harvest  | 75 - 85  | 90  | - 100  | 
  | 
  | 
  | |
Discharge: 5 minutes into Freeze  | 230 - 250  | 275 - 295  | |
  | 
  | 
  | |
Discharge: Minimum in Harvest  | 100  | 110  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Number of Evaporators:
6
Refrigerant Charge
288 ounces of 
Typical Compressor Amps, single phase
freeze 15 - 16
harvest 22 - 23
Typical Compressor Amps, three phase
freeze 9 - 10
harvest 13 - 14
Typical Harvest Ice Weight
19.2 lb.
Superheat
The TXV will control a nominal superheat point that can vary unit to unit from 11oF. to 17oF.
While controlling that point the superheat can also range + or - 4oF. without affecting performance.
Hi Pressure Control - Automatic Reset
Hi Pressure Cut Out - 450 PSIG
Hi Pressure Cut In - 350 PSIG
Headmaster Valve
Setting is 240 PSIG
March 2003
Page 37