Scotsman Ice specifications CME1356R and CME1656R, Electrical

Models: CME1656R CME1356R

1 47
Download 47 pages 16.42 Kb
Page 14
Image 14
Electrical

CME1356R and CME1656R

Electrical

All models must be installed with the correct wire size and type per the National Electric Code. Locate the nameplate on the back of the cabinet and find the numbers for Voltage, Phase, Minimum Circuit Ampacity and Maximum Fuse Size. Either fuses or HACR type circuit breakers may be used.

The ice maker is designed to operate on its own electrical circuit and must be individually fused. Voltage variation must not exceed the limits listed on page 2.

The remote condenser is designed to be powered from the ice machine. A separate knockout hole has been provided in the ice maker electrical junction box.

Remote Condenser

Power Connection

Note: Central Condensers connected to more than one refrigeration system will likely have a wiring scheme to control the fan motor. Follow those directions for condenser wiring.

Electrical connections are made in the junction box in the back of the cabinet.

1.Remove the junction box cover.

2.Knock out both holes for a field supplied strain relief.

3.Install wires and strain reliefs per code. Note: Condenser fan motor wires are tagged.

4.Connect to wires and secure ground wire to ground screw inside junction box.

All external wiring should conform to the national, state and local electrical code requirements. Usually an electrical permit and the services of a licensed electrician will be required.

Power Supply

Interconnecting

Wire

May 2001

Page 14

Page 14
Image 14
Scotsman Ice specifications CME1356R and CME1656R, Electrical