1.11 Basket Lift Service Procedures (cont.)

ULTIMATE ELECTRIC SERIES FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.11 Basket Lift Service Procedures (cont.)

Simplified Schematic

HN

Normally Open Upper-limit

Microswitch

5

M

6

1 or 4

 

 

 

Basket Lift

 

3

Relay

Normally Closed Lower-limit

 

Microswitch

To computer/controller via

interface board

When the product button is pushed on the computer/controller, current flows through a coil in the basket lift relay, causing the lower circuit to be activated. The basket lift lowers, closing the normally open upper-microswitch. When the lower normally closed microswitch is opened by the downward moving lift rod, power to the motor ceases to flow. When the computer/controller times- out, the current to the relay coil is interrupted, allowing the upper circuit to be activated. The basket lift then raises and closes the lower microswitch. When the basket lift rod clears the upper microswitch, the microswitch opens, and power to the circuit is interrupted, stopping the motor. Pushing the product button or activating the manual control (if equipped) restarts the cycle.

Problems with the modular basket lift design can be grouped into three categories:

Binding/jamming problems

Motor and gear problems

Electronics problems

1-14