1.13 Probe Resistance Chart

ULTIMATE ELECTRIC SERIES FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.13 Probe Resistance Chart

Use the chart below when testing temperature probes and probe circuits for proper operation.

Probe Resistance Chart

F

OHMS

C

 

F

OHMS

C

 

F

OHMS

C

 

F

OHMS

C

 

F

OHMS

C

60

1059

16

 

130

1204

54

 

200

1350

93

 

270

1493

132

 

340

1634

171

65

1070

18

 

135

1216

57

 

205

1361

96

 

275

1503

135

 

345

1644

174

70

1080

21

 

140

1226

60

 

210

1371

99

 

280

1514

138

 

350

1654

177

75

1091

24

 

145

1237

63

 

215

1381

102

 

285

1524

141

 

355

1664

179

80

1101

27

 

150

1247

66

 

220

1391

104

 

290

1534

143

 

360

1674

182

85

1112

29

 

155

1258

68

 

225

1402

107

 

295

1544

146

 

365

1684

185

90

1122

32

 

160

1268

71

 

230

1412

110

 

300

1554

149

 

370

1694

188

95

1133

35

 

165

1278

74

 

235

1422

113

 

305

1564

152

 

375

1704

191

100

1143

38

 

170

1289

77

 

240

1432

116

 

310

1574

154

 

380

1714

193

105

1154

41

 

175

1299

79

 

245

1442

118

 

315

1584

157

 

385

1724

196

110

1164

43

 

180

1309

82

 

250

1453

121

 

320

1594

160

 

390

1734

199

115

1174

46

 

185

1320

85

 

255

1463

124

 

325

1604

163

 

395

1744

202

120

1185

49

 

190

1330

88

 

260

1473

127

 

330

1614

166

 

400

1754

204

125

1195

52

 

195

1340

91

 

265

1483

129

 

335

1624

168

 

405

1764

207

1.14 Element Wattage/Amperage Calculation Charts

Use the charts below when changing voltages or determining amperage for a given element configuration.

L1

Three Phase

Amperage

Probe Resistance ChartL2

1.14 Element Wattage/Amperage Calculation ChartsL3

To determine Three Phase Amperage, solve for Single Phase first:

Wattage

= Single Phase Amps

Voltage

 

Then divide the Single Phase Amperage by 1.73 to determine Three Phase Amperage.

Example:

17,000W

=

70.833 Amps

240V

 

1.73

= 40.944 Amps per Phase

L1

Three Phase

Wattage

Three PhaseL2

Manual backgroundL3

To compute the New Wattage Rating of an element if a different voltage is applied, use the following formula:

[NewOld VoltageVoltage

]2

X kW Listed

= New Wattage Rating

Example:

If 208V supply is applied to a 17 kW element rated for 240V, the calculation is as follows:

[

208V

] 2

X 17,000 Watts

240V

= 12.77 kW

 

1-18

Page 23
Image 23
Frymaster Ultimate Electric Series Probe Resistance Chart, Element Wattage/Amperage Calculation Charts, Service Procedures