CME1356R and CME1656R

Bin Control: Installation

The bin control is a thermostat. It must be field installed after the ice machine has been placed on the bin.

Before starting, remove the left front panel and any baffle in the bin.

1.Locate bin thermostat bulb.

2.Route bulb thru routing tube (located between the compressor and the reservoir).

3.Locate bin thermostat bracket.

4.Carefully position the thermostat bulb on the bracket (see the diagram on the next page).

5.Fasten the bracket to the bottom of the ice machine with the two 3-pronged knobs supplied with the unit.

6.Pull back into the ice machine any excess capillary tubing.

7.Return the baffle to the bin and continue with the installation.

Note: If the machine is located at an altitude higher than 2,000 ft., adjust the thermostat by removing the plastic cover and rotating the adjustment screw per the table.

Thermostat Bulb Routing Tube

Bin Thermostat Altitude Correction Table

CW Turns of Range Screw (under plastic cover)

Feet

Turns

Feet

Turns

 

 

 

 

2000

55o

8000

340o

4000

160o

9000

385o

6000

250o

10000

405o

Use This Table to Adjust Thermostat

Bin Thermostat Bulb

Bin

Thermostat

Body

Thermostat Bulb

Routing Tube

Route Bin Thermostat Bulb Into Bin