In compliance with (EM)

Europe:

USA:

Approved by

Canada:

Mains unit

Input voltage Power/current consumption Output voltage Secondary output current Temperature range

In compliance with

Europe:

USA:

Canada:

Certified by cCSAus KL, 60065, CSA.

Specifications

EMC

EN 301489-1/-9

Radio

EN 300422-1/-2

Safety

EN 60065

47 CFR 15 subpart B

 

 

Industry Canada

RSS 210, IC: 2099A-G3SKMEM

 

 

100 to 240 V~, 50/60 Hz max. 120 mA

12 V

400 mA

–10°C to +40°C

EMC

EN 55022, EN 55024,

 

EN 55014-1/-2

Safety

EN 60065

47 CFR 15 subpart B

ICES 003

For accessories and information on connector assignment, visit the ew G3 product page at www.sennheiser.com.

SK 500 and SKM 500

RF characteristics

Modulation

wideband FM

Frequency ranges

 

516–558, 566–608, 626–668, 734–776,

 

 

780–822, 823–865 MHz (A to E, G, see page 4)

Transmission frequencies

 

 

1,680 frequencies, tuneable in steps of 25 kHz

 

 

20 frequency banks, each with up to 32 factory-preset

 

 

channels, intermodulation-free

 

 

 

 

 

6 frequency banks, each with up to 32 user program-

 

 

mable channels

Switching bandwidth

 

 

 

42 MHz

Nominal/peak deviation

 

±24 kHz/±48 kHz

Frequency stability

 

 

 

±15 ppm

RF output power at 50 Ω

 

 

 

typ. 10/30 mW, switchable

Pilot tone squelch

 

can be switched off

33