INDICATORS AND DISPLAY MESSAGES

If one of the following indicators lights up or one of the following messages appears in the display, check the meaning of the indicator or message in the following table and take appropriate action.

TD cartridge replacement required indicator

Drum cartridge replacement required indicator

 

 

Maintenance

 

 

Display

 

 

indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Paper required indicator

Misfeed indicator

 

 

 

 

 

 

 

 

 

 

Indication

 

Cause and solution

Page

 

 

 

 

 

 

 

 

 

Maintenance

Steadily

Service by an authorized SHARP service technician is

 

indicator

lit

required.

 

 

 

 

 

 

 

 

 

 

 

TD cartridge

Steadily

Replacement of TD cartridge will be needed soon. Prepare

 

 

replacement

lit

a new cartridge.

53

 

 

 

 

 

 

required indicator

 

Blinking

TD cartridge must be replaced. Replace it with a new one.

 

 

 

 

 

 

 

 

 

Drum cartridge

Steadily

Replacement of drum cartridge will be needed soon.

 

 

replacement

lit

Prepare a new cartridge.

54

 

 

 

 

 

 

required indicator

 

Blinking

Drum cartridge must be replaced. Replace it with a new one.

 

 

 

 

 

 

 

 

 

 

Paper required

Steadily

The tray is out of paper. Load paper. It is also possible that

 

 

the tray is not inserted completely into the machine. Make

14

 

indicator

lit

 

sure it is inserted correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Misfeed indicator

Blinking

A paper misfeed has occurred. Remove the misfeed as

47

 

explained in "MISFEED REMOVAL".

 

 

 

 

 

 

 

 

 

 

 

 

 

ORIGINAL SIZE indicator

 

The original is not placed in the correct orientation. Rotate

 

Blinking

the original so that it is in the same orientation as the

18,19

 

 

 

 

blinking ORIGINAL SIZE indicator.

 

 

 

 

 

 

 

 

 

 

 

 

 

A blinking PAPER SIZE indicator means that the size of paper

 

 

 

 

 

loaded in the tray is different from the paper size setting for the

 

PAPER SIZE indicator

Blinking

tray. Change the paper size setting.

16

To clear the display, do one of the following:

Use the [TRAY SELECT] key () to change the tray selection.

Open and close the tray.

Press the [CLEAR ALL] key ().

 

 

 

 

 

 

Steadily

The front cover or the side cover is open. Close the front

 

 

 

 

 

 

lit

cover or the side cover.

 

 

 

 

 

 

 

[CH] appears in display

 

 

 

 

TD cartridge is not installed correctly. Reinstall TD cartridge.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

If [CH] still blinks in the display after reinstalling TD

53

 

 

 

 

 

 

 

cartridge, contact a SHARP service center.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn off the power switch, wait about 10 seconds, and then

 

 

Letters and numbers appear

turn on the switch again. If this does not clear the message,

 

 

write down the code that appears and then unplug the

 

in the display

power cord and contact your SHARP service center. Tell

 

 

 

 

 

 

 

 

 

your SHARP service center what code appeared and the

 

 

 

 

 

 

 

 

circumstances under which it appeared.

 

 

 

 

 

 

 

 

 

When "Use close paper size" is disabled

 

 

 

ORIGINAL

PAPER

Press the [TRAY SELECT] key ( ) to manually select the

Online

 

SIZE

SIZE

 

bypass tray and then press the [ON LINE] key. Printing will

 

11X17

manual

 

X14

 

 

begin.

 

X11

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

X11

 

 

 

EXTRA

 

 

46