Industry Automation and Drive Technologies - SCE

pause with the MDS¹

remains set

Switching the reader aerial on/off

Command

 

Sub_command

 

length

address_MDS

DAT_DB

Comment

(hex)

 

 

 

[dec]

[hex]

[dec]

 

 

 

 

 

 

 

 

 

0A

01

= switch on aerial

-

 

-

-

The command Aerial

 

02

= standby:

 

 

 

 

on/off can not be started

 

Switch aerial off

 

 

 

 

with command repetition

 

 

 

 

 

 

 

(refer to chapter

 

 

 

 

 

 

 

"Command Repetition)

 

09

= adjust aerial to

 

 

 

 

Only Reader 80 (MOBY

 

the environment (FFT)

 

 

 

 

F)

 

 

 

 

 

 

 

 

Transponder Status

Command

Sub_command

length

address_MDS [hex]

DAT_DB [dec]

Comment

(hex)

 

[dec]

 

 

 

 

 

 

 

 

 

0B

00 = status and

-

Today’ s date

Pointer to

only MOBY U

 

diagnosis

 

(week/year) to

result. The

(refer to

 

 

 

calculate the life of

result is

chapter "The

 

 

 

the battery (for

represented

UDTs of

 

 

 

example, 1401 hex

with UDT 100

FB45“ )

 

 

 

= 20th week of year

 

 

 

 

 

2001)

 

 

 

01 = type and write

-

-

Pointer to

RF 300

 

protection status

 

 

result. The

(refer to

 

 

 

 

result is

chapter "The

 

 

 

 

represented

UDTs of

 

 

 

 

with UDT 260

FB45“ )

 

02 = diagnosis data

-

-

Pointer to

RF 300

 

 

 

 

result. The

(refer to

 

 

 

 

result is

chapter "The

 

 

 

 

represented

UDTs of

 

 

 

 

with UDT 270

FB45” )

(In our example, we are using the German language UDT261 and UDT271 for RF300)

Notes

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

TIA Training Document

Page 38 of 65

Module E11

 

Status: 01/2010

Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and

RF180C

 

Page 38
Image 38
Siemens DP, S7-300F-2 PN manual Switching the reader aerial on/off, Transponder Status