Industry Automation and Drive Technologies - SCE

Variable

 

 

Description

 

 

 

 

multitag

MOBY U/D or RF300; maximum number of MDS processed in parallel in the field. Permissible

 

values: 1

 

 

field_ON_control

MOBY U: BERO operating mode; aerial field is switched on/off automatically. The command

 

"Aerial ON/OFF“ is overlaid by the BERO operating mode.

 

00 hex

=

Without BEROs; no reader synchronization

 

01 hex

=

One or two BEROs;

 

 

 

The BEROs are logically ored. While a BERO is operated, the field is

 

 

 

switched on

 

02 hex

=

One or two BEROs.

 

 

 

The 1st BERO switches the field on and the 2nd BERO switches the

 

 

 

field off. If there are 2 BEROs and one field_ON_time is parameterized,

 

 

 

the field is switched off automatically if the 2nd BERO does not switch

 

 

 

within the BERO time.

 

 

 

If no field_ON_time is parameterized, the field remains switched on until

 

 

 

the 2nd BERO is operated.

 

03 hex

=

Activate reader synchronization by means of cable connection (refer to

 

 

 

manual for Configuration, Installation and Service for MOBY U)

 

MOBY D or RF300: 00 hex (reserved)

field_ON_time

MOBY U: time for BERO operating mode (field_ON_control = 02)

 

00 hex

=

Time monitoring is switched off. For field switch-off, the 2nd BERO is

 

 

 

needed.

 

01 hex .. FF hex

=

1...255s switch-on time for the Reader field

 

MOBY D: MDS type

 

 

00 hex

=

I-code 1 (for example, MDS D139)

 

01 hex

=

ISO MDS

 

RF300: 00 hex (reserved)

reserved

Reserved

 

 

Notes

Parameter “field_ON_time“ value = 0 for MDS type RF300 ___________________________

Parameter “field_ON_time“ value = 1 for MDS type ISO______________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

TIA Training Document

Page 45 of 65

Module E11

 

Status: 01/2010

Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and

RF180C

 

Page 45
Image 45
Siemens S7-300F-2 PN, DP manual Iso Mds