Additional indications

The displays indicate to the user the progress of a command. Error analyses are easy to perform.

Variable

 

 

 

 

Description

 

 

 

 

 

 

IM_busy

This bit is set when the IM processes a command. Normally, "IM_busy“ is inverted to "ready“.

 

IM_busy is indicated by the IM by means of the cyclical word (refer to chapter "Cyclical Control

 

Word between Master and MOBY IM“ under "IM_busy“). If processing takes place with the

 

automatic command start repeat_command, this bit indicates the processing of a new MDS with

 

the command that is to be executed.

 

 

command_rep_active

The IM is just executing a command repetition. The bit is set as a response to the control variable

 

repeat_command. After init_run, FB45 first resets the command_rep_active; it is set again

 

delayed since FB45 first transmits the MOBY commands to the IM.

number_MDS

MOBY U/D or RF300:

 

 

 

The number of MDSs is indicated that are presently located in the transmission window.

 

If more than 15 MDSs are in the field, the display number_MDS stops at 0F hex.

error_MOBY

The IM signaled this error. As a rule, this error is indicated also on the ERR LED on the IM

 

channel display (refer to chapter "Error Indications and Error Search“).

error_FB

Error indication from FB45 (refer to chapter "Error Indications and Error Search“).

error_BUS

The transmission path between FB45 and the IM signals an error. As a rule, this is a PROFIBUS

 

error (refer to chapter "Error Indications and Error Search“). This error is indicated by the system

 

functions SFC 58/59.

 

 

 

 

version_MOBY

Display of the firmware version of the MOBY IM. The value entered here is updated after every IM

 

power-up . It is ASCII encoded.

 

 

 

Example:

DBB26

DBB27

 

 

 

 

31 hex

 

30

Version 1.0

 

 

 

 

 

hex

 

 

 

 

"1“

"0“

 

 

 

 

 

 

 

 

Notes

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

All other UDT 11 variables are for internal FB use only.

The user must not change them at all.