Control bits from Bit8 to Bit15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANZ_MDS_present

Indicates the presence of an MDS in the transmission window of the Read/Write MDS.

 

 

 

 

 

 

 

 

 

 

 

 

 

ANZ_MDS_present is indicated only if the user set the INPUT parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

MDS_control.

 

 

 

 

 

 

 

 

 

 

 

 

 

Please note that when init_run is executed, the ANZ_MDS_present indication briefly

 

 

 

 

 

 

 

 

 

 

 

 

 

disappears even if an MDS stays permanently in the transmission window.

 

 

 

 

 

 

 

 

ANZ_cancel

The command executed last was a command interruption (cancel).The bit is set if the

 

 

 

 

 

 

 

 

 

 

 

 

 

IM displays a cancel acknowledgement by means of the cyclical word (refer to chapter

 

 

 

 

 

 

 

 

 

 

 

 

 

"Cyclical Control Word between Master and MOBY IM“. Reset is automatic by starting

 

 

 

 

 

 

 

 

 

 

 

 

 

a new command.

 

 

 

 

 

 

 

 

ANZ_ECC

Only MOBY I:

 

 

 

 

 

 

 

 

 

 

 

 

 

If the ECC driver is switched on (INPUT parameter "ECC mode“ = TRUE), the bit

 

 

 

 

 

 

 

 

 

 

 

 

 

indicates that the data read by the MDS was corrected. ANZ_ECC is not an error

 

 

 

 

 

 

 

 

 

 

 

 

 

indication since the data is OK. ANZ_ECC indicates that in the near future the MDS

 

 

 

 

 

 

 

 

 

 

 

 

 

memory that was just processed may completely fail.

 

 

 

 

 

 

 

 

reserved

Presently not assigned

 

 

 

 

 

 

 

 

LR_bat

This bit is of significance only if at MOBY I processing takes place with the MDS507.

 

 

 

 

 

 

 

 

 

 

 

 

 

It indicates an empty MDS507 dialog battery. For all other MDSs, this bit can take on

 

 

 

 

 

 

 

 

 

 

 

 

 

any state.

 

 

 

 

 

 

 

 

battery_low

Only for MOBY I/V with RAM MDS

 

 

 

 

 

 

 

 

 

 

 

 

 

The back-up battery of the RAM MDS is below the threshold. Although it is still

 

 

 

 

 

 

 

 

 

 

 

 

 

possible to process several months at room temperature with the remaining capacity,

 

 

 

 

 

 

 

 

 

 

 

 

 

it is recommended to immediately change the battery or to replace the MDS if the

 

 

 

 

 

 

 

 

 

 

 

 

 

battery can’t be changed.

 

 

 

 

 

 

 

 

error

FB45 sets this bit if a command is concluded faulty. The error bit is the sum error bit

 

 

 

 

 

 

 

 

 

 

 

 

 

for all occurring errors. The exact cause for the error is located in the variable

 

 

 

 

 

 

 

 

 

 

 

 

 

error_MOBY, error_FB or error_BUS (refer also to chapter "Additional Indications“ or

 

 

 

 

 

 

 

 

 

 

 

 

 

chapter "Error Indications and Error Search“). Restarting the command resets the

 

 

 

 

 

 

 

 

 

 

 

 

 

error bit.

 

 

 

 

 

 

 

 

ready

Ready indication: after ready = TRUE was indicated, the error bit = FALSE has to be

 

 

 

 

 

 

 

 

 

 

 

 

 

polled. This ensures that the command was processed without error.

 

 

 

 

 

 

 

 

 

 

 

 

 

Please note:

 

 

 

 

 

 

 

 

 

 

 

 

 

The ready bit does not have to be set for starting init_run or cancel.

 

Notes

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

TIA Training Document

Page 49 of 65

Module E11

 

Status: 01/2010

Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and

RF180C

 

Page 49
Image 49