Industry Automation and Drive Technologies - SCE
TIA Training Document
Page 37 of 65
Module E11
Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and
RF180C
was read.
Initialize Transponder
Command
(hex)
Sub_command length
[dec]
address_MDS [hex] DAT_DB [dec] Comment
03 00 to FF hex
value that is
written to the
MDS
- Memory size of the
MDS to be initialized
-
Read out Reader status
Command
(hex)
Sub_command length
[dec]
address_MDS [hex] DAT_DB [dec] Comment
04 01 = status according to
UDT 110¹
02 = status according to
UDT 120¹ (last
commands)
03 = status according to
UDT 130¹ (error
indications)
04 = status according to
UDT 140¹ (MDS in the
field)
05 = status according to
UDT 150 (communication
quality)
06 = status according to
UDT 280 (diagnosis data)
Pointer to the
result. The
result is
represented
with the
corresponding
UDT (refer to
sub_command
)
MOBY U/D or
RF300
MOBY U
MOBY U
MOBY U
RF300
(In our example, we are using the German language UDT111 and UDT281 for RF300) Command NEXT
Command
(hex)
Sub_command length
[dec]
address_MDS
[hex]
DAT_DB
[dec]
Comment
06 - - - - NEXT: processing
this MDS is
completed
Command END
Command
(hex)
Sub_command length
[dec]
address_MDS
[hex]
DAT_DB
[dec]
Comment
08 00 = Processing
with the MDS is
ended
01 = Processing
- - - ANZ_MDS_present
is reset
ANZ_MDS_present