To Enable Automatic System Recovery

1.At the sc> prompt, type:

sc> setsc diag-mode normal sc> setsc diag-level max

sc> setsc diag-trigger power-on-reset

2. At the ok prompt, type:

ok setenv auto-boot true

ok setenv auto-boot-on-error? true

Note – For more information about OpenBoot configuration variables, refer to the SPARC Enterprise T1000 Server Service Manual.

3.To cause the parameter changes to take effect, type:

ok reset-all

The system permanently stores the parameter changes and boots automatically when the OpenBoot configuration variable auto-boot?is set to true (its default value).

Note – To store parameter changes, you can also power cycle the system using the front panel Power button.

To Disable Automatic System Recovery

1.At the ok prompt, type:

ok setenv auto-boot-on-error? false

2.To cause the parameter changes to take effect, type:

ok reset-all

The system permanently stores the parameter change.

34 SPARC Enterprise T1000 Server Administration Guide • April 2007