Displaying System Fault Information

ALOM CMT software enables you to display current valid system faults. The showfaults command displays the fault ID, the faulted FRU device, and the fault message to standard output. The showfaults command also displays POST results.

To Display System Fault Information

Type showfaults

For example:

sc> showfaults

 

 

ID FRU

Fault

 

0

FT0.F2

SYS_FAN at FT0.F2 has FAILED.

 

Adding the –voption displays additional information,

 

 

 

sc> showfaults -v

 

 

ID Time

FRU

Fault

0

MAY 20 10:47:32 FT0.F2

SYS_FAN at FT0.F2 has FAILED.

 

 

 

 

For more information about the showfaults command, refer to the Advanced Lights Out Management (ALOM) CMT v1.3 Guide.

Multipathing Software

Multipathing software enables you to define and control redundant physical paths to I/O devices, such as storage devices and network interfaces. If the active path to a device becomes unavailable, the software can automatically switch to an alternate path to maintain availability. This capability is known as automatic failover. To take advantage of multipathing capabilities, you must configure the server with redundant hardware, such as redundant network interfaces or two host bus adapters connected to the same dual-ported storage array.

For your server, three different types of multipathing software are available:

Chapter 2 Managing RAS Features and System Firmware 37