Parameters

Ring No Reply Timer

Configurable time in seconds after which the ringing status is displayed for a telephone. When the phone rings, its status is IDLE until the Ring Seen Timer expires. Once the timer has expired, the telephone displays its "Ringing" status.

Ring Seen Timer

Configurable time in seconds after which the "Presence" status is dis- played for the telephone. For example, if the time is set to five seconds, this means that the "Absent" status is displayed if a call rings for more than five seconds.

Rollover type

How should a trunk key react if a trunk is busy and the call is signalled at a second trunk? The following options are available:

No ring

Alert ring

Route

Enter the first or second destination address preset for a Æ Router.

RTP Packet Size

The packet size is entered as a time unit. You can select the values auto, 10 ms and 20 ms.

Screen saver filename

This cannot be configured for all optiPoint phones.

Enter the name of the file that you want to use as your screen saver.

The file must be saved on the Æ FTPserver in a specific directory.

Valid file types: GIF, JPG.

Secondary DNS server address

Alternative address to Æ DNS server address.

65

Page 65
Image 65
Siemens V1.2.33 manual Ring No Reply Timer, Ring Seen Timer, Rollover type, Route, RTP Packet Size, Screen saver filename