Parameter name

Description

 

Value range

Default value

T

R

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

H.Position Offset

Save the offset value for H.Position

0

- 100

50

*

-

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

H.Width Offset

Save the offset value for H.Width

0

- 100

50

*

*

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

H.Period Offset

Save the offset value for H.Period

0

- 100

50

*

*

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

H.Back Porch Offset

Save the offset value for H.Back Porch

0

- 100

50

-

*

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

V.Position Offset

Save the offset value for V.Position

0

- 100

50

*

-

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

V.Width Offset

Save the offset value for V.Width

0

- 100

50

*

*

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

V.Period Offset

Save the offset value for V.Period

0

- 100

50

*

*

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

V.Back Porch Offset

Save the offset value for V.Back Porch

0

- 100

50

-

*

 

setting that you may have configured

 

 

 

 

 

 

from LCD menu.

 

 

 

 

 

 

 

0

: 8-72MHz

 

 

 

PLLGAIN_H

Specify the PLLGAIN VCO Range.

1

: 16-144MHz

1

*

-

2

: 16-144MHz

 

 

 

 

 

 

 

3

: 24-215MHz

 

 

 

PLLGAIN_L

Specify the PLLGAIN Charge Pump

0

- 7

6

*

-

 

Current.

 

 

 

 

 

 

Specify the ADC PLL Divider ratio.

 

 

 

 

 

PLLDIV

Usually, equivalent to the value of

0

- 65535

1687

*

-

 

H.Period minus one.

 

 

 

 

 

CLPDLY

Specify the Clamp Pulse Delay.

0

- 255

8

*

-

CLPDUR

Specify the Clamp Pulse width.

0

- 255

32

*

-

HSOPW

Specify a pulse width of ADC HSOUT.

0

- 255

96

*

-

SYNC_CTRL

Perform a synchronization control.

0

- 255

64

*

-

PHASE_CC

Specify the PHASE for image sampling.

0

- 255

0

*

-

 

 

300, 600, 1200, 2400, 4800,

 

 

 

Baudrate

Specify a baudrate.

9600, 14400, 19200, 38400,

19200

*

*

 

 

57600, 115200

 

 

 

Bit length

Specify a bit length.

8, 7

8

*

*

Stop bit

Specify a stop bit.

1, 2

1

*

*

Parity

Specify a parity check method.

None, Odd, Even

None

*

*

Flow control

Specify a flow control method.

None, XON/XOFF, RTS/CTS

None

*

*

Data Timeout

Specify a serial input timeout by

50-1000

100

*

*

 

millisecond.

 

 

 

 

 

Buffer level

Specify the number of buffer for

16 - 64

64

*

*

 

retransmission.

 

 

 

 

 

Node List Method

Specify a node search method.

Dynamic, Static

Dynamic

*

*

Static Node 0 - 7

Specify an IP address for node when

IP Address

0.0.0.0

*

*

 

Node List Method is set to Static.

 

 

 

 

 