C

ABLES

B-4Straight-Through Wiring

If the twisted-pair cable is to join two ports and only one of the ports has

an internal crossover (MDI-X), the two pairs of wires must be

straight-through. (When auto-negotiation is enabled for any RJ-45 port on

this switch, you can use either straight-through or crossover cable to

connect to any device type.)

Figure B-2. Straight-through Wiring

Crossover Wiring

If the twisted-pair cable is to join two ports and either both por ts are

labeled with an “X” (MDI-X) or neither port is labeled with an “X”

(MDI), a crossover must be implemented in the wiring. (When

auto-negotiation is enabled for any RJ-45 port on this switch, you can use

either straight-through or crossover cable to connect to any device type.)

Figure B-3. Crossover Wiring

White/OrangeStripe
Orange
White/GreenStripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
EIA
/
TIA568B RJ-45 Wiring
S
tandard
10/100BASE-TXStraight-through Cable
EndA EndB
White/OrangeStripe
Orange
White/GreenStripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
EIA
/
TIA568B RJ-45 Wiring
S
tandard
10/100BASE-TXCrossover Cable