5.Optionally adjust the Heartbeat Interval to control how often the two units communicate. The default is 5000 milliseconds; the minimum recommended value is 1000 milliseconds. Less than this may cause unnecessary failovers, especially when the SonicWALL is under a heavy load.

6.Set the Probe Level for the interval in seconds between communication with upstream or downstream systems. SonicWALL recommends that you set the interval for at least 5 seconds. You can set the Probe IP Address(es) on the High Availability > Monitoring screen.

7.Typically, SonicWALL recommends leaving the Failover Trigger Level (missed heartbeats), Election Delay Time (seconds), and Dynamic Route Hold-Down Time fields to their default settings. These fields can be tuned later as necessary for your specific network environment.

-The Failover Trigger Level sets the number of heartbeats that can be missed before failing over.

-The Election Delay Time is the number of seconds allowed for internal processing between the two units in the HA pair before one of them takes the primary role.

-The Dynamic Route Hold-Down Time setting is used when a failover occurs on a HA pair that is using either RIP or OSPF dynamic routing. When a failover occurs, Dynamic Route Hold-Down Time is the number of seconds the newly-active appliance keeps the dynamic routes it had previously learned in its route table. During this time, the newly-active appliance relearns the dynamic routes in the network. When the Dynamic Route Hold-Down Time duration expires, it deletes the

old routes and implements the new routes it has learned from RIP or OSPF. The default value is

45 seconds. In large or complex networks, a larger value may improve network stability during a failover.

8.Click the Include Certificates/Keys checkbox to have the appliances synchronize all certificates and keys.

9.Click Synchronize Settings to synchronize the settings between the Primary and Backup appliances.

10.Click Synchronize Firmware if you previously uploaded new firmware to your Primary unit while the Secondary unit was offline, and it is now online and ready to upgrade to the new firmware. Synchronize Firmware is typically used after taking your Secondary appliance offline while you test a new firmware version on the Primary unit before upgrading both units to it.

11.Click Apply to retain the settings on this screen.

Page 30 Configuring a State Sync Pair in NAT/Route Mode

Page 31
Image 31
SonicWALL 3500, NSA 5000, 4500 manual Configuring a State Sync Pair in NAT/Route Mode