Troubleshooting and Maintenance 6 Chapter
Troubleshooting
If an alarm message appears on the monitor screen, or if the unit appears to be malfunctioning, please check the following before contacting your Sony dealer.
Tape problems
Symptom | Cause | Remedy | ||
|
|
| ||
Recording is not | The cassette’s REC/SAVE switch is set | Set the REC/SAVE switch to REC, or use another cassette. | ||
possible. | to SAVE. |
|
| |
|
|
| ||
The unit’s tape | The REMOTE indicator in the display | Set the LOCAL/REMOTE switch to LOCAL to turn the | ||
transport control | section is lit and the LOCAL ENABLE | REMOTE indicator off, or change the setting of the LOCAL | ||
buttons (PLAY, F FWD, | menu item is set to STOP & EJECT or | ENABLE menu item (see page 65) to ALL ENABLE. | ||
REW, etc.) do not | ALL DISABLE. |
|
| |
work. |
|
|
| |
No cassette is loaded. | Insert a cassette (see page 29). | |||
| ||||
|
|
|
| |
The NO EDIT indicator | The audio recording mode selected on | • | When your current purpose is editing, set the LOCAL/ | |
on the front panel lights | this unit does not coincides with that of |
| REMOTE switch to LOCAL to turn the REMOTE indicator | |
up. | the loaded tape. |
| off and set the unit for the same audio recording mode as | |
|
|
| with the tape using the REC MODE menu item (see page | |
|
|
| 71), then set the switch to REMOTE to light the REMOTE | |
|
|
| indicator again. | |
|
| • | When your current purpose is recording, you can use the | |
|
|
| tape currently loaded in the unit. | |
|
|
| ||
| The recording format of the currently | Replace the tape with one recorded in the DVCAM format. | ||
| loaded tape is DV or DVCPRO. |
|
| |
|
|
| ||
| The recording format selected on this | Select the DVCAM format. | ||
| unit is DV (SP). |
|
| |
|
|
|
| |
|
|
|
| |
Time data problems |
|
|
| |
|
|
| ||
Symptom | Cause | Remedy | ||
|
|
| ||
Cannot freely set the | The TC MODE menu item is set to EXT | Change the setting of the TC MODE menu item (see page | ||
initial time data value. | REGEN. | 68) to INT PRESET. | ||
|
|
| ||
| CNT is selected as the time data type | Press the COUNTER SELECT button to make the TC or U- | ||
| to be displayed (the COUNTER time | BIT time data type indicator light up (the CNT value cannot | ||
| data type indicator is lit). | be set freely). | ||
|
|
| ||
| The REMOTE indicator in the display | Set the LOCAL/REMOTE switch to LOCAL to turn the | ||
| section is lit and the LOCAL ENABLE | REMOTE indicator off or change the setting of the LOCAL | ||
| menu item is set to STOP & EJECT or | ENABLE menu item (see page 65) to ALL ENABLE. | ||
| ALL DISABLE. |
|
| |
|
|
| ||
The tape is running, | The MENU button or TC PRESET | Press the button once again to exit the menu control mode, | ||
but the time data is not | button in the menu control section has | time code preset mode, or digital hours meter display mode. | ||
shown in the time | been pressed. | (In either of the menu control mode and time code preset | ||
counter display. |
| mode, the time data is not shown in the time counter display.) | ||
|
|
| ||
| The | Press the COUNTER SELECT button to make the | ||
|
| COUNTER or TC time data type indicator light up. | ||
|
|
|
| |
|
|
|
| |
Input problem |
|
|
| |
|
|
| ||
Symptom | Cause | Remedy | ||
|
|
| ||
It is not possible to | No SDTI signal is input to the unit, or | Connect an SDTI signal to the SDI/SDTI (QSDI) IN | ||
record an SDTI (QSDI) | the SDTI format has not been selected. | connector, or set the DIGITAL OUTPUT menu item (see | ||
signal. |
| page 73) to SDTI. | ||
|
|
|
|
104 Troubleshooting